Reliability and validity of the SHFT running power meter

Publikation: Bidrag til tidsskriftTidsskriftartikelForskningfagfællebedømt

Standard

Reliability and validity of the SHFT running power meter. / Linkis, Jesper Emil; Bonne, Thomas Christian; Bejder, Jacob; Rasmussen, Esben Krogh; Breenfeldt Andersen, Andreas; Nordsborg, Nikolai Baastrup.

I: Sensors, Bind 21, Nr. 22, 7516, 2021.

Publikation: Bidrag til tidsskriftTidsskriftartikelForskningfagfællebedømt

Harvard

Linkis, JE, Bonne, TC, Bejder, J, Rasmussen, EK, Breenfeldt Andersen, A & Nordsborg, NB 2021, 'Reliability and validity of the SHFT running power meter', Sensors, bind 21, nr. 22, 7516. https://doi.org/10.3390/s21227516

APA

Linkis, J. E., Bonne, T. C., Bejder, J., Rasmussen, E. K., Breenfeldt Andersen, A., & Nordsborg, N. B. (2021). Reliability and validity of the SHFT running power meter. Sensors, 21(22), [7516]. https://doi.org/10.3390/s21227516

Vancouver

Linkis JE, Bonne TC, Bejder J, Rasmussen EK, Breenfeldt Andersen A, Nordsborg NB. Reliability and validity of the SHFT running power meter. Sensors. 2021;21(22). 7516. https://doi.org/10.3390/s21227516

Author

Linkis, Jesper Emil ; Bonne, Thomas Christian ; Bejder, Jacob ; Rasmussen, Esben Krogh ; Breenfeldt Andersen, Andreas ; Nordsborg, Nikolai Baastrup. / Reliability and validity of the SHFT running power meter. I: Sensors. 2021 ; Bind 21, Nr. 22.

Bibtex

@article{8bdeb199b4f544b6aa6f43d4b0c833a4,
title = "Reliability and validity of the SHFT running power meter",
abstract = "The SHFT device is a novel running wearable consisting of two pods connected to your smartphone issuing several running metrics based on accelerometer and gyroscope technology. The purpose of this study was to investigate the reliability and validity of the power output (PO) metric produced by the SHFT device. To assess reliability, 12 men ran on an outdoor track at 10.5 km·h-1 and 12 km·h-1 on two consecutive days. To assess validity, oxygen uptake (VO2) and SHFT data from eight men and seven women were collected during incremental submaximal running tests on an indoor treadmill on one to four separate days (34 tests in total). SHFT reliability on the outdoor track was strong with coefficients of variance (CV) of 1.8% and 2.4% for 10.5 and 12 km·h-1, respectively. We observed a very strong linear relationship between PO and VO2 (r2 = 0.54) within subjects, and a very strong linear relationship within each subject within each treadmill test (r2 = 0.80). We conclude that SHFT provides a reliable running power estimate and that a very strong relationship between SHFT-Power and metabolic rate exists, which places SHFT as one of the leading commercially available running power meters.",
keywords = "Faculty of Science, Sports technology, Sensors, Wearable, Running, Exercise, Training, Testing, Fitness device, Gadget",
author = "Linkis, {Jesper Emil} and Bonne, {Thomas Christian} and Jacob Bejder and Rasmussen, {Esben Krogh} and {Breenfeldt Andersen}, Andreas and Nordsborg, {Nikolai Baastrup}",
note = "CURIS 2021 NEXS 360",
year = "2021",
doi = "10.3390/s21227516",
language = "English",
volume = "21",
journal = "Sensors",
issn = "1424-3210",
publisher = "M D P I AG",
number = "22",

}

RIS

TY - JOUR

T1 - Reliability and validity of the SHFT running power meter

AU - Linkis, Jesper Emil

AU - Bonne, Thomas Christian

AU - Bejder, Jacob

AU - Rasmussen, Esben Krogh

AU - Breenfeldt Andersen, Andreas

AU - Nordsborg, Nikolai Baastrup

N1 - CURIS 2021 NEXS 360

PY - 2021

Y1 - 2021

N2 - The SHFT device is a novel running wearable consisting of two pods connected to your smartphone issuing several running metrics based on accelerometer and gyroscope technology. The purpose of this study was to investigate the reliability and validity of the power output (PO) metric produced by the SHFT device. To assess reliability, 12 men ran on an outdoor track at 10.5 km·h-1 and 12 km·h-1 on two consecutive days. To assess validity, oxygen uptake (VO2) and SHFT data from eight men and seven women were collected during incremental submaximal running tests on an indoor treadmill on one to four separate days (34 tests in total). SHFT reliability on the outdoor track was strong with coefficients of variance (CV) of 1.8% and 2.4% for 10.5 and 12 km·h-1, respectively. We observed a very strong linear relationship between PO and VO2 (r2 = 0.54) within subjects, and a very strong linear relationship within each subject within each treadmill test (r2 = 0.80). We conclude that SHFT provides a reliable running power estimate and that a very strong relationship between SHFT-Power and metabolic rate exists, which places SHFT as one of the leading commercially available running power meters.

AB - The SHFT device is a novel running wearable consisting of two pods connected to your smartphone issuing several running metrics based on accelerometer and gyroscope technology. The purpose of this study was to investigate the reliability and validity of the power output (PO) metric produced by the SHFT device. To assess reliability, 12 men ran on an outdoor track at 10.5 km·h-1 and 12 km·h-1 on two consecutive days. To assess validity, oxygen uptake (VO2) and SHFT data from eight men and seven women were collected during incremental submaximal running tests on an indoor treadmill on one to four separate days (34 tests in total). SHFT reliability on the outdoor track was strong with coefficients of variance (CV) of 1.8% and 2.4% for 10.5 and 12 km·h-1, respectively. We observed a very strong linear relationship between PO and VO2 (r2 = 0.54) within subjects, and a very strong linear relationship within each subject within each treadmill test (r2 = 0.80). We conclude that SHFT provides a reliable running power estimate and that a very strong relationship between SHFT-Power and metabolic rate exists, which places SHFT as one of the leading commercially available running power meters.

KW - Faculty of Science

KW - Sports technology

KW - Sensors

KW - Wearable

KW - Running

KW - Exercise

KW - Training

KW - Testing

KW - Fitness device

KW - Gadget

U2 - 10.3390/s21227516

DO - 10.3390/s21227516

M3 - Journal article

C2 - 34833596

VL - 21

JO - Sensors

JF - Sensors

SN - 1424-3210

IS - 22

M1 - 7516

ER -

ID: 285712468