Column-switching high-performance liquid chromatographic assay for determination of apigenin and acacetin in human urine with ultraviolet absorbance detection

Publikation: Bidrag til tidsskriftTidsskriftartikelForskningfagfællebedømt

Standard

Column-switching high-performance liquid chromatographic assay for determination of apigenin and acacetin in human urine with ultraviolet absorbance detection. / Nielsen, Salka E; Dragsted, Lars Ove.

I: Journal of Chromatography B: Biomedical Sciences and Applications, Bind 713, Nr. 2, 1998, s. 379-386.

Publikation: Bidrag til tidsskriftTidsskriftartikelForskningfagfællebedømt

Harvard

Nielsen, SE & Dragsted, LO 1998, 'Column-switching high-performance liquid chromatographic assay for determination of apigenin and acacetin in human urine with ultraviolet absorbance detection', Journal of Chromatography B: Biomedical Sciences and Applications, bind 713, nr. 2, s. 379-386. https://doi.org/10.1016/S0378-4347(98)00187-X

APA

Nielsen, S. E., & Dragsted, L. O. (1998). Column-switching high-performance liquid chromatographic assay for determination of apigenin and acacetin in human urine with ultraviolet absorbance detection. Journal of Chromatography B: Biomedical Sciences and Applications, 713(2), 379-386. https://doi.org/10.1016/S0378-4347(98)00187-X

Vancouver

Nielsen SE, Dragsted LO. Column-switching high-performance liquid chromatographic assay for determination of apigenin and acacetin in human urine with ultraviolet absorbance detection. Journal of Chromatography B: Biomedical Sciences and Applications. 1998;713(2):379-386. https://doi.org/10.1016/S0378-4347(98)00187-X

Author

Nielsen, Salka E ; Dragsted, Lars Ove. / Column-switching high-performance liquid chromatographic assay for determination of apigenin and acacetin in human urine with ultraviolet absorbance detection. I: Journal of Chromatography B: Biomedical Sciences and Applications. 1998 ; Bind 713, Nr. 2. s. 379-386.

Bibtex

@article{9ef772a722e341b49e0052d2aebd5742,
title = "Column-switching high-performance liquid chromatographic assay for determination of apigenin and acacetin in human urine with ultraviolet absorbance detection",
abstract = "A high-performance liquid chromatographic (HPLC) method is described for the determination of apigenin and the 4'-methylated derivative acacetin in human urine using column-switching and ultraviolet (UV) absorbance detection. Urine samples were enzymatically hydrolysed and solid-phase extracted prior to injection onto the HPLC system. Prior to elution of apigenin and the internal standard, 5,7,8-trihydroxyflavone, from the first column used for sample clean-up, the six-port valve was switched to the second column for analysis with UV detection. Detection of apigenin was precise and reproducible, with a limit of quantification of 10 ngml-1 urine. Detection and quantification of acacetin was linear down to 70 ngml-1 urine. The method has been successfully applied to determine the level of apigenin in 100 human urine samples from an intervention study with parsley. Copyright (C) 1998 Elsevier Science B.V.",
keywords = "Acacetin, Apigenin",
author = "Nielsen, {Salka E} and Dragsted, {Lars Ove}",
note = "(Ekstern)",
year = "1998",
doi = "10.1016/S0378-4347(98)00187-X",
language = "English",
volume = "713",
pages = "379--386",
journal = "Journal of Chromatography - Biomedical Applications",
issn = "0378-4347",
publisher = "Elsevier",
number = "2",

}

RIS

TY - JOUR

T1 - Column-switching high-performance liquid chromatographic assay for determination of apigenin and acacetin in human urine with ultraviolet absorbance detection

AU - Nielsen, Salka E

AU - Dragsted, Lars Ove

N1 - (Ekstern)

PY - 1998

Y1 - 1998

N2 - A high-performance liquid chromatographic (HPLC) method is described for the determination of apigenin and the 4'-methylated derivative acacetin in human urine using column-switching and ultraviolet (UV) absorbance detection. Urine samples were enzymatically hydrolysed and solid-phase extracted prior to injection onto the HPLC system. Prior to elution of apigenin and the internal standard, 5,7,8-trihydroxyflavone, from the first column used for sample clean-up, the six-port valve was switched to the second column for analysis with UV detection. Detection of apigenin was precise and reproducible, with a limit of quantification of 10 ngml-1 urine. Detection and quantification of acacetin was linear down to 70 ngml-1 urine. The method has been successfully applied to determine the level of apigenin in 100 human urine samples from an intervention study with parsley. Copyright (C) 1998 Elsevier Science B.V.

AB - A high-performance liquid chromatographic (HPLC) method is described for the determination of apigenin and the 4'-methylated derivative acacetin in human urine using column-switching and ultraviolet (UV) absorbance detection. Urine samples were enzymatically hydrolysed and solid-phase extracted prior to injection onto the HPLC system. Prior to elution of apigenin and the internal standard, 5,7,8-trihydroxyflavone, from the first column used for sample clean-up, the six-port valve was switched to the second column for analysis with UV detection. Detection of apigenin was precise and reproducible, with a limit of quantification of 10 ngml-1 urine. Detection and quantification of acacetin was linear down to 70 ngml-1 urine. The method has been successfully applied to determine the level of apigenin in 100 human urine samples from an intervention study with parsley. Copyright (C) 1998 Elsevier Science B.V.

KW - Acacetin

KW - Apigenin

UR - http://www.scopus.com/inward/record.url?scp=0032424649&partnerID=8YFLogxK

U2 - 10.1016/S0378-4347(98)00187-X

DO - 10.1016/S0378-4347(98)00187-X

M3 - Journal article

C2 - 9746253

AN - SCOPUS:0032424649

VL - 713

SP - 379

EP - 386

JO - Journal of Chromatography - Biomedical Applications

JF - Journal of Chromatography - Biomedical Applications

SN - 0378-4347

IS - 2

ER -

ID: 254771801